Air conditioning not cooling: what to check before calling
If your air conditioner blows but does not cool, first check that it is in cooling mode with a low set point, that the remote has batteries and that the filters are clean. If nothing changes, there may be dirt in the units, a refrigerant leak or a failed component, and it needs a professional diagnosis.
Updated on 18 October 2026. Informational guide: it does not replace a professional assessment or the official text of the rules cited.
Safety notice: Switch the unit off and isolate it at the breaker or the plug before cleaning the filters or getting close to the unit. Do not open the outdoor unit or tamper with the refrigerant circuit: do not top up gas yourself. If there is ice, do not break it off or switch the unit back on.
The causes range from a dirty filter to a refrigerant leak. This guide helps you rule out the simple things, recognise the signs of a fault and understand which part of the repair only a certified professional can do.
First, rule out the simple things (5 minutes)
- Mode and temperature. Check it is in cooling mode (not 'dry' or 'fan') with a set point clearly below the room temperature.
- Remote and batteries. Low batteries can send wrong commands or none.
- Indoor unit filters. With the unit off and isolated at the breaker or the plug, remove them, wash in lukewarm water, dry completely and refit. A clogged filter reduces airflow and cooling capacity.
- Closed room. With doors or windows open to the outside the unit cannot keep up with the heat coming in.
- Clear outdoor unit. No leaves, objects or dirt against the grille, and air able to flow around it.
Causes that need a diagnosis
- Dirty heat exchangers (indoor or outdoor): they collect dust, grease or salt and transfer heat less well. On the seafront, salt air speeds up corrosion of outdoor coils.
- Refrigerant leak. If gas is missing, capacity drops and ice can form on pipes or the indoor unit. Refrigerant is not 'used up': if it is low, there is a leak to find and repair.
- A failed component: fan, capacitor, compressor, sensor or control board.
- An undersized unit for the floor area, orientation or actual use of the room.
- A blocked condensate drain, which can cause dripping and protective shutdowns.
What the rules say about refrigerant
Handling fluorinated gases (the refrigerants in most units) is regulated. The EU applies Regulation (EU) 2024/573, in force since 11 March 2024, which replaced Regulation 517/2014 and strengthens leak checks and restrictions on use. In Spain, Royal Decree 115/2017 requires certification for the people and companies that install, service, repair or recover these gases in air conditioning equipment.
In practice: topping up gas yourself, or through someone without certification, is neither legal nor advisable, and refilling without repairing the leak only delays the problem and releases refrigerant into the atmosphere.
As for servicing, the RITE (Royal Decree 1027/2007) regulates the maintenance of thermal installations above certain power thresholds (5 kW and 70 kW, with different requirements in each band). What applies to you depends on the power of your specific installation.
Common mistakes that make the fault worse
- Keeping the unit running when there is visible ice or dripping: it can damage the compressor or cause water damage.
- Topping up gas without finding the leak.
- Cleaning coils with harsh products or a pressure washer: the fins bend easily.
- Covering the outdoor unit or installing it without room to ventilate.
- Skipping the yearly service: small problems add up and show up during the heatwave.
How a professional usually approaches it
A structured diagnosis starts simple and moves to the complex: check set points and filter condition, measure temperatures and the temperature drop between intake and outlet air, inspect heat exchangers, drain and fans and, if needed, check pressures and look for leaks with the proper procedure and equipment. The result decides between cleaning, repair or replacement.
When to call a professional
- You have cleaned the filters and checked mode and temperature and it still does not cool.
- There is ice on the indoor unit or pipes, new noises, an odd smell or dripping.
- The breaker or RCD trips when you switch the unit on.
- The unit works but takes much longer than before to reach temperature.
Related services: Air conditioning repair in Estepona · Air conditioning in Estepona and the Costa del Sol
Send us a photo and your area on WhatsApp: we will advise you and give you a quote. We reply within 2 hours during working hours (Monday to Friday, 8:00 to 18:00; Saturdays, 8:00 to 16:00, excluding public holidays).
Frequently asked questions
Why does it blow air but not cool?
It can be dirty filters or outdoor unit, low refrigerant or a failed component. It needs to be checked.
Does an older unit cool less?
It can lose performance over the years and without servicing. A check-up shows whether repair is worthwhile.
How do I book a check-up?
Message us on WhatsApp with a photo of the unit and what is happening.
Can I top up the gas myself if it does not cool?
No. If gas is missing, there is a leak to find and repair, and refilling without repairing it only delays the problem. It is a job for a professional.
Sources and rules cited
- Regulation (EU) 2024/573 on fluorinated greenhouse gases
- Royal Decree 115/2017 (fluorinated gases), BOE
- RITE, Royal Decree 1027/2007, BOE
- MITECO: information note on fluorinated gases for the air conditioning sector